@article { author = {Shahbazi-Gahrouei, Daryoush and Nazem, Masoud and Sharbafchizadeh, Mohammad and Jafarpishehfard, Mohmmad Saleh}, title = {The Average of Cumulative Radiation Dose in Neonates in the Neonatal Surgery Ward Due to Diagnostic and Therapeutic Radiologic Procedures During the Admission Period}, journal = {Journal of Isfahan Medical School}, volume = {29}, number = {140}, pages = {626-633}, year = {2011}, publisher = {Isfahan University of Medical Sciences}, issn = {1027-7595}, eissn = {1735-854X}, doi = {}, abstract = {Background: The carcinogenic effect of radiation is directly related to the exposure rate and the risk is even more in infants. The scope of the present study is to evaluate of the average of cumulative radiation dose in neonates in the neonatal surgery ward due to diagnostic and therapeutic radiologic procedures during the admission period, in Alzahra hospital of Isfahan, Iran.Methods: This investigation was a descriptive study on 168 neonates. It was done in neonatal surgery ward during last 9 months of 2009 in Alzahra hospital of Isfahan, Iran. The patients were selected randomly and with no attention to age, sex, diagnose and admision time. Thermo luminescent dosimeters (TLD GR200), were used for dosimetry and each chips was putted in a plastic envelope on the neonate sternum during the admission period. The cumulative absorbed dose by each patient was stored during the admission by TLD and followed by reading by TLD reader. For using of TLDs, they were calibrated and two calibration factors (individual and batch) were performed in radiotherapy section of Seyed Al-shohada hospital of Isfahan, Iran. After checking the accuracy of calibration, the absorbed dose by each patient was achieved by using of calibration factors.Finding: The average of admission time for each patient was 7.64 days and the average of cumulative absorbed dose was 3.13 Millisievert (mSv) during this time. The maximum absorbed dose in one patient was 42.83 mSv. The average number of conventional radiography for each patient was 2.77. The average of conventional radiography and cumulative absorbed dose in patient with no examination or just simple x-ray examinations was 2.58 and 0.863 mSv, respectively. Chest x-ray examination was the most examination used here (338 person). The average dose for each chest x-ray examination was 0.313 mSv. The average of cumulative absorbed dose among patients with fluoroscopic examination was about 12.6 mSv. The cumulative absorbed dose in 19 patients was more than 10 mSv.Conclusion: The average of cumulative absorbed dose was not more than the dose limit according to reference levels, but in comparison with other medical centers in the world is very high. Therefore, it is necessary to pay more attention to reduce radiological imaging procedures, particularly about fluoroscopic procedures.  }, keywords = {X-ray,Cumulative dose,Conventional radiography,Fluoroscopy}, title_fa = {میزان متوسط دوز تجمعی پرتوی دریافتی در نوزادان بستری در بخش جراحی نوزادان به دنبال انجام رادیوگرافی‌های تشخیصی و درمانی در طول مدت بستری}, abstract_fa = {مقدمه: مهم‌ترین عارضه‌ی دریافت بیش از حد پرتو ایکس افزایش خطر بروز بدخیمی‌ها و به خصوص انواع سرطان‌ها است. بخش جراحی نوزادان بیمارستان الزهرا (س) محل بستری نوزادانی است که دچار انواع بیماری‌های جراحی هستند و تحت انجام انواع روش‌های تصویربرداری، از گرافی ساده تا فلوروسکوپی و CT اسکن قرار می‌گیرند. ممکن است در حین انجام روش‌های تصویربرداری معمول پرتو ایکس، آسیب‌های پرتوی اتفاق بیفتد. با توجه به میزان پرتودهی دستگاه‌های رادیولوژی موجود و تعداد و انواع گرافی‌های به عمل آمده برای نوزادان بخش جراحی نوزادان مرکز پزشکی الزهرا (س) اصفهان، هدف این مطالعه تعیین متوسط دوز تجمعی دریافتی توسط نوزادان بود.روش‌ها: این مطالعه به صورت توصیفی و آینده‌نگر، در بخش جراحی نوزادان بیمارستان الزهرا (س)، با حجم نمونه‌ی 168 نفر صورت پذیرفت. اندازه‌گیری دوز جذبی پرتو در سطح بدن به کمک دوزیمتر ترمولومینسانس (TLD مدل 200GR) انجام گرفت.یافته‌ها: متوسط مدت بستری نوزادان مورد مطالعه 64/7 روز بود. بیشترین رادیوگرافی به عمل آمده رادیوگرافی قفسه‌ی صدری با تعداد کل 338 عدد بود. متوسط تعداد رادیوگرافی‌های ساده برای هر نوزاد در طول مدت بستری 77/2 عدد بود. متوسط دوز دریافتی پرتو ایکس توسط نوزادان در طول مدت بستری معادل 13/3 میلی‌سیورت (Millisievert یا mSv) و بیشترین میزان دوز پرتو برای یک نوزاد معادل 83/42 میلی‌سیورت بود. متوسط دوز دریافتی در بیمارانی که فلوروسکوپی داشتند 6/12 میلی‌سیورت و در بیمارانی که تنها رادیوگرافی ساده داشتند یا رادیوگرافی نداشتند 863/0 میلی‌سیورت بود.نتیجه‌گیری: متوسط دوز دریافتی برای این بیماران در طول مدت بستری، تا حداکثر دوز مجاز سالانه فاصله زیادی دارد، اما در مقایسه‌ی با سایر مراکز مشابه در دنیا دوز قابل توجهی است. متوسط دوز دریافتی برای بیمارانی که فلوروسکوپی داشتند بسیار بالا و عامل خطر بود.}, keywords_fa = {پرتو ایکس,دوز تجمعی,رادیوگرافی‌ ساده,فلوروسکوپی}, url = {https://jims.mui.ac.ir/article_13436.html}, eprint = {https://jims.mui.ac.ir/article_13436_92a0105cc5f59b831c8aeefbb0bb3d24.pdf} }