<ArticleTitle>Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening</ArticleTitle>
<VernacularTitle>Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening</VernacularTitle>
			<FirstPage>1813</FirstPage>
			<LastPage>1817</LastPage>
			<ELocationID EIdType="pii">13927</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mehrdad</FirstName>
					<LastName>Masoudifar</LastName>
<Affiliation>Assistant Professor, Department of Anesthesiology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-4360-5507</Identifier>

</Author>
<Author>
					<FirstName>Reyhanak</FirstName>
					<LastName>Talakoub</LastName>
<Affiliation>Associate Professor, Department of Anesthesiology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Payam</FirstName>
					<LastName>Ebrahimifar</LastName>
<Affiliation>Student of Medicine, School of Medicine AND Student Research Committee, Isfahan University of Medical Sciences, Isfahan, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2012</Year>
					<Month>07</Month>
					<Day>08</Day>
				</PubDate>
			</History>
		<Abstract>Background: We evaluated the correlation between intracranial pressure (ICP) measured by Schiotz tonometer and computed tomography (CT) scan findings in craniotomy patients. Methods: This cross-sectional study was performed in Alzahra Hospital in Isfahan from 2010 to 2011. We included the elective craniotomy patients aged 18-64 years with the American Society of Anesthesiologists (ASA) physical status I or II. After being evaluated by CT scan, ICP was studied with Schiotz tonometer in Burr hole before dura opening. Findings: 58 patients (mean age: 44.37 ± 11.53 years) scheduled for elective craniotomy were included in the study. There were 36 males (62.1%) and 22 females (37.9%). The results showed significant correlation between ICP measured by Schiotz tonometer and by CT scan (r = 0.913, P &lt; 0.001). Conclusion: This study showed that Schiotz tonometer could consider as a safe and reliable alternative to CT scan in ICP evaluation. Keywords: Intracranial pressure, Schiotz tonometer, X-ray computed tomography</Abstract>
			<OtherAbstract Language="FA">Background: We evaluated the correlation between intracranial pressure (ICP) measured by Schiotz tonometer and computed tomography (CT) scan findings in craniotomy patients. Methods: This cross-sectional study was performed in Alzahra Hospital in Isfahan from 2010 to 2011. We included the elective craniotomy patients aged 18-64 years with the American Society of Anesthesiologists (ASA) physical status I or II. After being evaluated by CT scan, ICP was studied with Schiotz tonometer in Burr hole before dura opening. Findings: 58 patients (mean age: 44.37 ± 11.53 years) scheduled for elective craniotomy were included in the study. There were 36 males (62.1%) and 22 females (37.9%). The results showed significant correlation between ICP measured by Schiotz tonometer and by CT scan (r = 0.913, P &lt; 0.001). Conclusion: This study showed that Schiotz tonometer could consider as a safe and reliable alternative to CT scan in ICP evaluation. Keywords: Intracranial pressure, Schiotz tonometer, X-ray computed tomography</OtherAbstract>