<ArticleTitle>Local Comparison of Cup-to-Disc Ratio in Right and Left Eyes via Optical Coherence Tomography B-Scans of Optic Nerve Head</ArticleTitle>
<VernacularTitle>مقایسه‌ی محلی نسبت کاپ به دیسک چشم چپ و راست افراد سالم با استفاده از تصاویر Optical Coherence Tomography (OCT)</VernacularTitle>
			<FirstPage>2381</FirstPage>
			<LastPage>2387</LastPage>
			<ELocationID EIdType="pii">14850</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>مرضیه</FirstName>
					<LastName>مختاری</LastName>
<Affiliation>دانشجوی کارشناسی ارشد، گروه بیوالکتریک و مهندسی پزشکی، دانشکده‌ی فن‌آوری‌های نوین علوم پزشکی و کمیته‌ی تحقیقات دانشجویی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</Affiliation>

</Author>
<Author>
					<FirstName>حسین</FirstName>
					<LastName>ربانی</LastName>
<Affiliation>دانشیار، گروه بیوالکتریک و مهندسی پزشکی، دانشکده‌ی فن‌آوری‌های نوین پزشکی و مرکز تحقیقات پردازش سیگنال و تصاویر پزشکی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</Affiliation>
<Identifier Source="ORCID">0000-0001-8756-4922</Identifier>

</Author>
<Author>
					<FirstName>علیرضا</FirstName>
					<LastName>مهری دهنوی</LastName>
<Affiliation>دانشیار، گروه بیوالکتریک و مهندسی پزشکی، دانشکده‌ی فن‌آوری‌های نوین پزشکی و مرکز تحقیقات پردازش سیگنال و تصاویر پزشکی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</Affiliation>

</Author>
<Author>
					<FirstName>محمدرضا</FirstName>
					<LastName>اخلاقی</LastName>
<Affiliation>دانشیار ،گروه چشم‌پزشکی، دانشکده‌ی پزشکی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2015</Year>
					<Month>10</Month>
					<Day>03</Day>
				</PubDate>
			</History>
		<Abstract>Background: The symmetricity of even organs of body may help clinicians in the early detection of diseases. So, we estimated the cup-to-disk ratio (CDR) in left and right eyes and checked the symmetricity between the two eyes using the data of optical coherence tomography (OCT).Methods: In this study, data from 40 normal subjects were used. This data was taken from the 3D-OCT1000 Tapcon model. For estimating CDR in each B-scan, at first the internal limiting membrane (ILM) and retinal pigment epithelium (RPE) layers were extracted; then using the end-point of RPE layer and the depth of cup, the boundary of disk and cup were determined. Finally, CDR of each B-scan was compared point-by-point and the symmetricity parameters were evaluated.Findings: CDRs in the left and right eyes of 40 normal data were investigated locally. We divided optic disk area into three regions named upper, middle and lower. Then, CDR of each region was calculated for left and right eyes of each patient. The local CDR were 0.433 ± 0.0548, 0.432 ± 0.061, and 0.432 ± 0.0635 for the right eyes and 0.441 ± 0.0635, 0.443 ± 0.0731, and 0.417 ± 0.675 for the left eyes in upper, middle and lower regions, respectively. The differences between local CDRs in different regions of the two eyes were 0.0483± 0.042, 0.0420 ± 0.039, and 0.067 ± 0.045, respectively.Conclusion: The results of local comparison of CDRs between the left and right eyes indicated that the level of asymmetricity in the lower region of disk was higher than upper and middle regions, and the middle region has the most symmetricity. In addition, in point-by-point symmetricity evaluation of CDRs, the highest level of symmetricity is seen in the second B-scan, near the center of optic disk.</Abstract>
			<OtherAbstract Language="FA">مقدمه: بررسی تقارن در عضوهایی از بدن که به صورت زوج وجود دارد، می‌تواند در تشخیص زودهنگام بیماری‌ها به پزشکان کمک کند. در این مطالعه، حد آستانه‌ی تقارن با محاسبه‌ی نسبت کاپ به دیسک در چشم افراد سالم با استفاده از داده‌های Optical coherence tomography (OCT) به صورت محلی و نقطه به نقطه با استفاده از هر B-scan بررسی شد.روش‌ها: در این مطالعه، 40 داده‌ی مربوط به افراد سالم که از دستگاه 3D-OCT1000 مدل تاپکن استخراج شده بود، مورد استفاده قرار گرفت. مراحل انجام کار به این صورت بود که با استخراج لایه‌ی Internal limiting membrane (ILM) و Retinal pigment epithelium (RPE)، محدوده‌ی کاپ و دیسک به ازای هر B-scan محاسبه شد و سپس به ازای B-scanهای معادل در چشم‌های چپ و راست، این نسبت به صورت نقطه به نقطه، مقایسه و پارامترهای تقارن بررسی قرار گردید.یافته‌ها: نسبت کاپ به دیسک در سه ناحیه‌ی فوقانی، میانی و تحتانی برای چشم‌های چپ و راست به دست آمد که به ترتیب برای چشم راست 054/0 ± 433/0، 061/0 ± 432/0 و 063/0 ± 405/0 و برای چشم چپ، 063/0 ± 441/0، 073/0 ± 443/0 و 067/0 ± بود؛ میزان اختلاف این نسبت برای دو چشم به طور میانگین 042/0 ± 048/0، 038/0 ± 042/0 و 045/0 ± 067/0 بود.نتیجه‌گیری: عدم تقارن در قسمت تحتانی دیسک نسبت به قسمت فوقانی و میانی بیشتر است و در قسمت میانی، بیشترین تقارن دیده می‌شود. همچنین در بررسی نقطه به نقطه، بیشترین تقارن در دومین B-scan در قسمت تحتانی محور افقی بین مرکز دیسک نوری و ماکولا مشاهده می‌شود.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">ارزیابی عدم تقارن</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">نسبت کاپ به دیسک</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تصاویر Optical coherence tomography</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://jims.mui.ac.ir/article_14850_db0d4963149c89b0cc76ffd6aaacf002.pdf</ArchiveCopySource>
</Article>
</ArticleSet>