<ArticleTitle>An Evaluation on Complications and Patient Satisfaction of Port Catheter in Patients with Acute Leukemia in Alzahra and Milad Hospitals, Isfahan, Iran: A One-Year Prospective Analysis</ArticleTitle>
<VernacularTitle>An Evaluation on Complications and Patient Satisfaction of Port Catheter in Patients with Acute Leukemia in Alzahra and Milad Hospitals, Isfahan, Iran: A One-Year Prospective Analysis</VernacularTitle>
			<FirstPage>309</FirstPage>
			<LastPage>316</LastPage>
			<ELocationID EIdType="pii">15533</ELocationID>
			
<ELocationID EIdType="doi">10.22122/jims.v36i473.5365</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Valiollah</FirstName>
					<LastName>Mehrzad</LastName>
<Affiliation>Assistant Professor, Department of Internal Medicine, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Atefeh</FirstName>
					<LastName>Eshaghian</LastName>
<Affiliation>Student of Medicine, Student Research Committee, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Ali Akbar</FirstName>
					<LastName>Beigi</LastName>
<Affiliation>Associate Professor, Department of Surgeury, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2015</Year>
					<Month>07</Month>
					<Day>25</Day>
				</PubDate>
			</History>
		<Abstract>Background: Totally implantable central venous access (port-a-cath) is being used increasingly in patients with cancer for chemotherapy administration and other therapeutic procedures. We investigated the rate of port-related complications and patients’ satisfaction in these patients.Methods: We prospectively followed up 44 patients with acute leukemia who underwent port placement in Alzahra and Milad hospitals, Isfahan, Iran, between May 2012 and May 2013. Port-related complications were examined in detail and analyzed statistically. In order to evaluate the patients’ satisfaction, some questionnaires were filled in by patients.Findings: 46 port-a-caths were implanted in 44 patients. Two patients underwent a second placement after removal the first. No case of early complications was reported, in comparison to 16 cases (38.1%) of late complications consisted of rupture and/or migration (9.5%), thrombosis (11.9%), cellulitis (4.8%), bacteremia (14.3%), and erosion (2.4%). The mean patients’ satisfaction was 65.Conclusion: The most common complication reported in our study was the catheter-related blood stream infection. It is suggested that by multimodal educational programs for health care providers and patients, more than 50% of this complication could be avoided. Patients’ satisfaction relates to their background information, and incidence of complication.</Abstract>
			<OtherAbstract Language="FA">Background: Totally implantable central venous access (port-a-cath) is being used increasingly in patients with cancer for chemotherapy administration and other therapeutic procedures. We investigated the rate of port-related complications and patients’ satisfaction in these patients.Methods: We prospectively followed up 44 patients with acute leukemia who underwent port placement in Alzahra and Milad hospitals, Isfahan, Iran, between May 2012 and May 2013. Port-related complications were examined in detail and analyzed statistically. In order to evaluate the patients’ satisfaction, some questionnaires were filled in by patients.Findings: 46 port-a-caths were implanted in 44 patients. Two patients underwent a second placement after removal the first. No case of early complications was reported, in comparison to 16 cases (38.1%) of late complications consisted of rupture and/or migration (9.5%), thrombosis (11.9%), cellulitis (4.8%), bacteremia (14.3%), and erosion (2.4%). The mean patients’ satisfaction was 65.Conclusion: The most common complication reported in our study was the catheter-related blood stream infection. It is suggested that by multimodal educational programs for health care providers and patients, more than 50% of this complication could be avoided. Patients’ satisfaction relates to their background information, and incidence of complication.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Port catheters</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Leukemia</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Chemotherapy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Complications</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://jims.mui.ac.ir/article_15533_5b4e201ba2043c100c2a63f677074aca.pdf</ArchiveCopySource>
</Article>
</ArticleSet>