<ArticleTitle>Phantom-Based Validation of a T2∗ MRI Relaxometry Protocol for the Clinical Assessment and Classification of Iron Overload in Thalassemia Major Patients</ArticleTitle>
<VernacularTitle>اعتبارسنجی پروتکل ام‌آرآی ریلکسومتری   بر اساس فانتوم جهت ارزیابی و طبقه‌بندی بالینی اضافه‌بار آهن در بیماران تالاسمی ماژور</VernacularTitle>
			<FirstPage>898</FirstPage>
			<LastPage>907</LastPage>
			<ELocationID EIdType="pii">33414</ELocationID>
			
<ELocationID EIdType="doi">10.48305/jims.v44.i865.0898</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>فرزانه</FirstName>
					<LastName>قربانی</LastName>
<Affiliation>استادیار فیزیک پزشکی، مرکز تحقیقات فیزیک پزشکی، دانشگاه علوم پزشکی مشهد، مشهد، ایران</Affiliation>
<Identifier Source="ORCID">0000-0003-4191-9868</Identifier>

</Author>
<Author>
					<FirstName>بهاره</FirstName>
					<LastName>شهرکی</LastName>
<Affiliation>کارشناسی ارشد فناوری تصویربرداری پزشکی، بخش تصویربرداری، بیمارستان امام علی ابن‌ابیطالب زاهدان، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران</Affiliation>
<Identifier Source="ORCID">0009-0009-8060-9185</Identifier>

</Author>
<Author>
					<FirstName>پگاه</FirstName>
					<LastName>لطفی</LastName>
<Affiliation>دانشجوی دکترای تخصصی فیزیک پزشکی، گروه فیزیک پزشکی، دانشکده‌ی پزشکی، دانشگاه علوم پزشکی مشهد، مشهد، ایران</Affiliation>
<Identifier Source="ORCID">0009-0007-9615-8732</Identifier>

</Author>
<Author>
					<FirstName>محمد</FirstName>
					<LastName>قربانی</LastName>
<Affiliation>استادیار خون‌شناسی آزمایشگاهی و بانک خون، گروه آسیب‌شناسی، دانشکده‌ی پزشکی، مرکز تحقیقات توسعه اجتماعی و ارتقاء سلامت دانشگاه علوم پزشکی گناباد، گناباد، ایران</Affiliation>
<Identifier Source="ORCID">0000-0001-8829-4258</Identifier>

</Author>
<Author>
					<FirstName>زهرا</FirstName>
					<LastName>بدیعی</LastName>
<Affiliation>دانشیار خون و سرطان کودکان، گروه هماتولوژی و آنکولوژی، دانشکده‌ی پزشکی، دانشگاه علوم پزشکی مشهد، مشهد، ایران</Affiliation>
<Identifier Source="ORCID">0000-0001-8617-4842</Identifier>

</Author>
<Author>
					<FirstName>علیرضا</FirstName>
					<LastName>منتظرابدی</LastName>
<Affiliation>دانشیار فیزیک پزشکی، مرکز تحقیقات فیزیک پزشکی، دانشگاه علوم پزشکی مشهد، مشهد، ایران</Affiliation>
<Identifier Source="ORCID">0000-0001-6756-0318</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>05</Month>
					<Day>20</Day>
				</PubDate>
			</History>
		    <Abstract>Background: Accurate hepatic iron overload assessment in thalassemia major patients is critical for optimal clinical management. While T_2^* based MRI relaxometry is the standard noninvasive reference for tissue iron quantification, T_2^* values vary with scanner, imaging protocol, and analysis method, potentially causing clinical misclassification. This study evaluated the necessity of quality control and site-specific correction coefficients.Methods: In this retrospective, observational, two-center study, hepatic iron concentration was quantified in 79 patients with β-thalassemia major from Mashhad and Zahedan using MRI relaxometry. Initially, images were analyzed without applying correction coefficients (non-modified) and patients were classified into five clinical severity groups based on T_2^* values. For quantitative validation, a phantom containing defined iron concentrations was imaged at both centers, and site-specific correction coefficients were derived from the relationship between phantom T_2^* values and actual iron concentration. Patient datasets were then reanalyzed by applying these coefficients (QC-modified), and classifications were updated accordingly.Findings: Applying the center-specific correction coefficients significantly altered clinical iron-overload categorization in 31.6% of patients. Without corrections, iron levels tended to be overestimated in the Zahedan center and underestimated in the Mashhad center. The phantom study confirmed a very strong correlation between T_2^* values and true iron concentration (R2 ≈ 0.98), confirming the accuracy of the calibration method.Conclusion: The findings highlight that phantom-based calibration and scanner-specific analysis play a pivotal role in enhancing the quantitative accuracy of MRI relaxometry and preventing diagnostic errors in thalassemia patients. Implementing scanner-specific analysis improves iron burden estimation and facilitates more precise clinical decisions regarding transfusion and chelation therapy.</Abstract>
			<OtherAbstract Language="FA">مقدمه: ارزیابی دقیق اضافه‌بار آهن کبد در بیماران تالاسمی ماژور جهت مدیریت بهینه درمان حیاتی است. اگرچه تصویربرداری تشدید مغناطیسی (MRI) مبتنی بر ریلکسومتری  روش استاندارد و غیرتهاجمی برای سنجش بار آهن بافتی است، اما مقادیر  ​ به شدت تحت تأثیر تفاوت‌های اسکنر، پروتکل تصویربرداری و روش آنالیز قرار دارند؛ امری که می‌تواند منجر به طبقه‌بندی بالینی نادرست شود. این مطالعه با هدف بررسی ضرورت کنترل کیفی و اعمال ضرایب تصحیح اختصاصی انجام شد.روش‌ها: در این مطالعه مشاهده‌ای گذشته‌نگر دو مرکزه، ۷۹ بیمار تالاسمی ماژور (مشهد و زاهدان) با استفاده از MRI-Relaxometry ارزیابی شدند. ابتدا تصاویر بدون اعمال ضرایب تصحیح (non-modified) تحلیل و بیماران در پنج طبقه بالینی دسته‌بندی شدند. برای اعتبارسنجی، فانتومی با غلظت‌های معین آهن در هر مرکز تصویربرداری و ضرایب تصحیح اختصاصی استخراج گردید. سپس، تصاویر مجدداً با اعمال این ضرایب (QC-modified) آنالیز و نتایج طبقه‌بندی بازنگری شد.یافته‌ها: اعمال ضرایب تصحیح، تغییر در طبقه‌بندی بالینی 31/6 درصد بیماران را در پی داشت. عدم لحاظ ضرایب اختصاصی منجر به بیش‌برآوردی در مرکز زاهدان و کم‌برآوردی در مرکز مشهد شد. همبستگی بسیار قوی میان  و غلظت واقعی آهن در فانتوم (0/98 ≈ R2)، دقت روش کالیبراسیون را تأیید کرد.نتیجه‌گیری: یافته‌ها مؤید آن بود که کالیبراسیون مبتنی بر فانتوم و آنالیز اختصاصی هر اسکنر، نقش کلیدی در افزایش دقت کمی MRI و پیشگیری از خطاهای تشخیصی دارد. این رویکرد ضمن ارتقای دقت سنجش بار آهن، تصمیم‌گیری بالینی دقیق‌تر در مدیریت تزریق خون و درمان آهن‌زدا را میسر می‌سازد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">تالاسمی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ریلکسومتری تشدید مغناطیسی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">اضافه‌بار آهن</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">کالیبراسیون</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">بیومارکر تصویربرداری کمی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://jims.mui.ac.ir/article_33414_706e79e774e8345ecccc7ed401793d9e.pdf</ArchiveCopySource>
</Article>
</ArticleSet>